Description
Overview
The EM Test UCS500N7 is an EMC Immunity Test equipment is an all in one box for testing EFT to 5.5kV, Surge to 7kV and 100kHz Ringwave to 6 kV, with built-in single phase coupler and software. This test equipment provides optional Dips and Interrupts testing with the V4780 S2 external variac. The UCS500N7 includes a built-in CDN for single phase it can be extended for testing three-phse DUT's by means of automatically controlled external coupling network up to 100A.
This Immunity Test Generator can be operated via the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow control an ongoing test sequences based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. This EMI test equipment provides a fully compliant that goes to levels beyond common testing requirements.
The UCS500n7 includes many reprogrammed test routines ideal for testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 61000-4-12, CEMark, ANSI/IEEE C62.41 cat. B, EN IEC 61000-6-1, and EN IEC 61000-6-2. This product also includes both pre-programmed standard tests and a quick start menu allowing for parameters to be changed on-line during the test to evaluate the susceptibility level of an individual DUT.
Data SheetUser ManualSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 61000-4-12, CE Mark, ANSI/IEEE C62.41 cat. B, EN 61000-6-1, -6-2 |
Integrated CDN: |
|
AC Voltage and Current |
300V/16A; 50/60Hz |
DC Voltage and Current |
300V/10A |
EFT Burst 5/50ns: |
|
Standards |
IEC 61000-4-5, ed.3, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±1.5ns, 50µs pulse width ±15ns |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±1.5ns, 50µs pulse width -15/+100ns |
Voltage Amplitude |
200V-5500 V ±10%, 100V-2,750V ±10% into 50Ω |
Burst Duration |
td = 0.10ms - 999ms |
Burst Period |
tr = 10ms - 9,999ms |
Frequency |
f = 0.1kHz - 1,000kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45, EN 61000-6-1, -6-2 |
Open Circuit Voltage Waveform |
1.2µs Front Time ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
8µ Front Time ±20%, 20µs Duration ± 20% |
Peak Open Circuit Voltage |
250V–7kV ±10% @2 Ω |
Peak Short Circuit Current |
125A–3.5kA ±10%@2 Ω |
Pulse Repetition Rate |
2s – 999s |
100 kHz Ringwave: |
|
Standards |
IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B, ANSI C62.45 |
Open Circuit Voltage Waveform |
100kHz Damped Cosine, Rise Time=.5µs±-30%, Damping= 40%/peak |
Peak Open Circuit Voltage |
250V–6kV ± 10% @12 Ω or @ 30 Ω |
Peak Short Circuit Current |
200A±10%@30 Ωohms, 500A ±10%@12 Ω |
Pulse Repetition Rate |
1s – 999s |
Dips and Interrupts: |
Optional External V4780 S2 |
Standards |
EN/IEC 61000-4-11 and EN 61000-6-1, -6-2 |
Voltage Dips: |
40%, 70%, 80% , 100%residual voltage ±5% |
Short Interrupts |
0% residual voltage ±5% |
Transition Time |
Rise Time, Fall Time ≥1µs & ≤5µs |
Input Voltage/Current |
50-250VAC, 50/60Hz, 16A Max. |
Weight |
29kg, 64 pounds |
Dimensions |
43x43x48cm, 17x17x19 inches |
All Accessories
Rent coupler decoupler networks (CDN)s & accessories from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
UCS 500N7 Full Accessory List
Item | Capabilities |
V4780 S2 |
EMTest automated external transformer for the UCS 500n7 and UCS 500n5 generators to perform the dips and interrupts test for EN IEC 61000-4-11. |
CNI 503 |
3PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE |
MV 2616 |
MOTORISED VARIAC FOR VOLTAGE VARIATION |
V 4780 | TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS |
V 4780S2 |
TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS |
CNV 504/508 |
SURGE COUPLING/DECOUPLING NETWORKS FOR SIGNAL/DATA LINES |
MS 100N |
MAGNETIC FIELD COIL FOR POWER-FREQUENCY AND PULSED MAGNETIC FIELDS |
HFK |
CAPACITIVE COUPLING CLAMP |
CA EFT KIT |
VERIFICATION KIT FOR EFT/BURST PULSES |
KW50 |
100:1 divider, 50 ohm |
KW1000 |
500:1 divider, 1,000 ohm |
CNV 504Nx |
Coupling network for 4 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
CNV 508Nx |
Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
CNI 508N2 Assembly |
Set of coupling/decoupling and protection networks for testing unshielded and shielded high-speed communication lines (Ethernet lines |
V 4780 |
Tapped autotransformer as per IEC 61000-4-11 Ed.2 |
V 4780 S2 |
Tapped autotransformer as per IEC 61000-4-11 Ed.2 with automatic change of tap |
Standards
Widely Used Standards
Below is a list of common standards for this conducted immunity generator. This is by no means the only standards that it can cover. Please confirm prior to renting as capabilities are often based upon accessories.
- ANSI/IEEE C62.41
- ECE-R10
- EN 61000-4-11
- EN 61000-4-12
- EN 61000-4-29
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-8
- EN 61000-4-9
- EN 61000-6-1
- EN 61000-6-2
- EN 61543
- IEC 60255-22-5
- IEC 61000-4-11
- IEC 61000-4-12
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- IEC 61008-1
- IEC 61009-1
- IEC 61326
- IEC 61850-3
- IEEE 1547
- ITU-T K.20
- ITU-T K.21
- ITU-T K.45
- UL 1741
- UL 244
- UL 943