Description
ECAT Surge/Combination Generator System Features
- Surge/Combination Wave Voltage up to 10 kV
- ISO 17025 Calibration included
- Includes - E103, E510 A, & E4554
- Compact & IEC/EN 61000-4-5 compliant
- Free Technical Support & 2 Days Free Transit
- E4554 3-phase: CDN 480V/32A
Thermo Keytek ECATS (ECAT E103, E510 A, E4551 kV) with the E 510 biwave surge to 10kV, 5kA, with integrated single phase coupler/decoupler. This system comes standard with an ISO 17025 accredited calibration and technical support.Thermo Keytek, E 510 Bi-wave Surge module to 10kV per IEC 61000-4-5 for the ECAT system, requires the E103 controller.
ECAT Data SheetSpecifications
Controller-E103 |
Controller for the ECAT system with front panel and software operation. |
E510A - Combination Wave Surge to |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI/IEEE C62.41.2 Cat. B, UL 1449 |
Open Circuit Voltage Waveform |
1.2µs, Front Time ± 30%, 50µs Duration ±20% |
Short Circuit Current Waveform |
8µs Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–10kV-5+10% |
Peak Short Circuit Current |
100A–5kA -0+10%@2 Ω, 20.8-550A -0+10%@12Ω |
Pulse Repetition Rate |
1 shot/18 seconds |
Weight |
121 kg, 55 pounds |
Dimensions |
42x52x21cm, 16x20 x8 inches |
E4554kV Three Phase Coupler/Decoupler |
|
Standards |
IEC 61000-4-5, EN 61000-4-5, ANSI/IEEE C62.41, UL 1449 |
Voltage |
480V/600V |
Current |
32A |
Monitoring |
Monitoring and peak detection of surge voltage across any two manually-selected lines. Monitoring can be at the EUT or at the front panel of the coupler/decoupler |
Dimensions |
42cm X 52cm X 21cm (20 3/8 X 16 ½ X 8 ¼ inches) |
ECAT Series
Common Modules
ECAT Series Full Accessory
Item | Capabilities |
ECAT Model E411 | EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV |
ECAT Model E412 | EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following: |
ECAT Model E421 | FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k |
ECAT Model E501B | Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA |
ECAT Model E502B | Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT |
ECAT Model E503 | Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864 |
ECAT Model E504A | Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module) |
ECAT Model E505A | Plug-in module that produces the lightning surge waveforms required by FCC Part 68 |
ECAT Model E506-4W | Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing |
ECAT Model E508 and E508-12P | Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE |
ECAT Model E510A | Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA |
ECAT Model E511 | Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards |
ECAT Model E513 | Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864 |
ECAT Model E514 | Surge simulator for 10/1000 µs current waves |
ECAT Model E515 | Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE |
ECAT Model E518 | Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT |
ECAT Models E521 and E522 | Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits). |
ECAT Model E551 | A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5 |
ECAT Models EP61 and EP62 | Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A |
ECAT Model E455x | Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5 |