Data SheetOverview
Modular test system with colour touch screen and intuitive software. An integrated help with graphics guide the user through fast and efficient setup and operation. The system is used for CE mark testing in the European Union. Each system can be individually configured and easily extended. 10 modules are available for the IMU-MGS. All modules are easily added or removed by the user on-site.
The generator can be configured for IEC / EN and also ANSI test requirements. ElectroMagnetic Compatibility (EMC) tests for Surge up to 5kV and EFT up to 5kV are freely configurable by the user. IMU-MGS is programmed with default parameters from the IEC basic standards. A test library including basic and generic requirements is also included in the IMU-MGS.
Specifications
Common Standards |
EN/IEC 61000-4-4 & EN/IEC 61000-4-5 |
IMU-MGS Mainframe |
|
EUT power input 1 (CDN) |
max. AC/DC 300V, 16A (fused 16A) with P module |
EUT power input 2 (CDN) |
max. AC/DC 300V, 16A (not fused) with P module |
Internal CDN freq. range |
DC, 50 Hz, 60 H |
Power freq. synchr |
50/60 Hz |
Coupling Burst |
L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct out |
Coupling Surge |
2 Ω: L-N, direct out, 12 Ω: L-PE, N-PE |
IMU-MGS Control Features |
|
Operating system |
EPOS propietary firmware |
EUT power monitor |
supply voltage, current and freq. on screen |
EUT supply current waveform |
monitoring BNC output connector max. 15 V |
EUT supply voltage waveform |
monitoring BNC output connector max. 15 V |
Surge voltage waveform |
monitoring BNC output connector max. 15 V |
Surge current waveform |
monitoring BNC output connector max. 15 V |
Trigger out |
BNC connector, max. 6 V |
Trigger in |
auto, manual or via programmable BNC |
Synchronization source |
EUT power, direct out, external |
Synchronization angle |
|
Standards
Common Standards for IMU Conducted Immunity Platform
- IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test.
- IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test.
- IEC 61000-4-5: Testing and measurement techniques - Surge immunity test.
- IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test.
- IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test.
- IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests.
- IEC 61000-4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0Hz to 150kHz.
- IEC 61000-4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.
- IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase