Description
Overview
The T1000 Magnetic-Field Susceptibility Transformer was designed to exceed the AF Magnetic Field susceptibility test requirements of DO 160 Section 19 and Boeing D6-16050 Section 7.2. It may also be used as a 10-to-1 step-down transformer for output current of up to 100ARMS.
The T1000 transformer provides up to 300A-m and is able to generate up to 100ARMS. The turns ratio provides a ten-to-one step down to the secondary winding.
The T1000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.
A 12-amp circuit breaker protects the unit against over-current conditions. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.
The T1000 transformer is for use by experienced staff.
Data SheetSpecifications
Common Standards |
DO 160 Section 19 & Boeing D6-16050-5 Section 7.2 standards |
Primary: |
200 VP maximum |
Secondary: |
20.0 VP maximum output |
Dielectric Test: |
1200 VDC |
Turns Ratio:: |
Ten-to-one step down |
Protection: |
Input power-protected via circuit breaker |
Input Terminals: |
4-way binding posts |
Output Terminals: |
Multi Contact 125A plugs |