Description
Overview
The BSR-3-480-32 is an automated 3-phase coupler decoupler network (CDN) designed for electrical fast transients/burst and surge testing to IEC 61000-4-4 and IEC 61000-4-5. This equipment is limited to 3 x 480 VAC with a current rating of 32 Amps 50/60 Hz for the EUT. It provides coupling in accordance with EN/IEC 61000-4-4, EN/IEC 61000-4-5, and EN/IEC 61000-4-12 for burst up to 5.5kV, surge and ring wave to 7kV. This network can be rented with the EM Test NX7 series, or individually to supplement testing needs. This system comes standard with a current ISO 17025 accredited calibration and associated documentation. This CDN can be controlled via the immunity generator or through control software via PC.
Data SheetUser ManualSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12 |
Three-phase CDN |
According to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and -4-12 for Burst up to 5.5 kV Surge and Ring wave up to 7 kV |
Current ranges* |
<32 A, 63 A, 125 A |
Connectors |
IN (AC): CEE 690/125, IN (DC): MC Safety plug 6 mm, OUT: MC Safety plug 6 mm |
EUT supply |
3 x 690 V, 125 A, 50/60 Hz 1,000 VDC, 125 A |
Dimensions |
Size: RAC 34 IEC included, Weight: approx. 250 kg |
INTERFACES |
|
Sys.link |
26 pin high density connector to control an external devices |
Connector EUT supply |
3 x 480 V, CEE plug, 16 A to 125 A, 3 x 690 V, CEE plug, 16 A to 63 A, plugs for all other current ratings |
Connector to EUT |
up to 32 A: 4 mm safety plug, 63 A: 6 mm safety plug, 125 A: 6 mm safety plug, 200 A: 10 mm safety plug |
MAINS (CONTROL) |
|
Supply voltage |
85 V - 264 V |
Frequency |
50/60 Hz |
Power |
approx. 75 W Standby: 100 mA |
Fuses |
115 V: 2 x 4 A slow blow, 230 V: 2 x 2 A slow blow |
SAFETY |
|
Safety standard |
IEC/EN 61010 |
Security circuit |
Control input (24 VDC) |
Warning lamp |
Floating contact (max. 60 V/2 A) |
ENVIRONMENT |
|
Temperature |
10 °C to 35 °C |
Humidity |
30 % to 75 %, non condensing |
Atmospheric pressure |
86 kPa (860 mbar) to 106 kPa (1,060 mbar |