Description
Overview
The Teseq CDN3425 (Teseq CCL) main purpose is to couple Burst/EFT pulses to data lines. It can also be used to couple to mains lines where no CDN is available; for example, high current lines >200 A. This coupling decoupling network (CDN) capacitive coupling clamp (CCL) comes with an ISO 17025 accredited calibration and works with a many conducted immunity generators.
The new design is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of EN/IEC 61000-4-4 Ed 3.0 to be published in 2012. This model also replaces earlier models CDN 8014 and CDN 8015.The coupling capacitance between the coupling clamp and the cable laid in it depends on the cable characteristics.
Data SheetUser ManualSpecifications
Common Standards |
EN/IEC 61000-4-4 |
Max. permissible burst voltage |
8 kV |
Usable length of the clamp |
1000mm |
Diameter of the test cable: |
4 to 40 mm |
Connectors |
SHV-NIM female, 50 Ω (on both ends) |
Distance to the earth reference plane |
100 mm |
Dimensions |
1100 x 200 x 110mm, 43.31 x 7.78 x 4.33in |
Weight |
7.5kg, 16.53lbs |