IMU Series Video Guides
EMC Partner IMU Platform
This video explains the newest series of IMU test platforms by EMC Partner. It explains both the options of the IMU platform as well as applications and modular design.
IMU Series Generators
This video provided by EMC Partner, the manufacturer of the IMU/TRA test systems, provides system information about the capabilites of the IMU4000 and TEMA3000 Control software.
Data Sheet User ManualAs a leader in immunity test equipment rentals, we offer rentals of a variety of transient test systems designed for testing up to 15kV and CDNs up to 125Amps. Our diverse inventory includes ISO 17025 calibrated equipment from Teseq, EM Test, Haefely, and EMC Partner.
Overview
The EMC Partner IMU4000 EMI (Optional: Common Mode) test generator is an all in one unit testing solution for testing to EFT to 4.4kV and Surge to 4.1kV with built-in single phase coupler, and Dips under 6 amps. A2LA accredited calibration is included in the EMC rental equipment price. This products "Plug and Play" architecture allows for system to automatically identify hardware then re-configure testing menu to reflect the change.
This Immunity Test Generator has been created for CE transient testing as well as fulfilling IEC basic standard requirements. The IMU 4000 includes both an Ethernet Port for control communication and test reporting that includes laboratory environmental conditions.This EMC tester is a environmentally conscience solution with low power consumption, less noise, and less heat.
The IMU 4000 is a single unit testing system for EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, and CE Mark. With the common mode available for testing to EN/IEC 61000-4-16 this design offers flexibility depending on testing needs. As an added bonus EMC Partner does not require proprietary software all reports are HTML based and can be viewed with web browsers.
Specifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, CE Mark, optional EN/IEC 61000-4-16 |
Control Features |
|
User Interface |
7” Colour touch panel |
Operating System |
EMC PARTNER (EPOS) |
Communication Interface |
Ethernet |
Accessory control interface |
RS485 |
Atmospheric measurement |
Temperature, humidity, pressure (with accessory) |
BNC monitor ports |
EUT plus IMPULSE voltage & current |
Synchro on / off |
0° up to 360° |
Integrated CDN: |
|
AC Voltage and Current |
300V/16A; 50 to 400Hz |
DC Voltage and Current |
300V/16A |
Maximum EUT current |
16A |
Frequency range |
DC up to 60Hz |
Power frequency synchro |
DC up to 60Hz |
Coupling EFT |
L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct |
Coupling CWG |
L-N, L-PE, N-PE, direct |
Additional Capabilities |
|
EFT Burst 5/50ns: |
|
Standards |
EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Amplitude |
250-4,400V ±10%, 125V-2,200V ±10% into 50Ω |
Burst Duration |
td = 0.10ms – 30ms |
Burst Period |
tr = 1ms – 1,000ms |
Frequency |
f = 0.1kHz - 1,000kHz |
Combination Wave Surge: |
|
Standards |
EN/IEC 61000-4-5 , EN 61000-6-1, -6-2, CEMark |
Open Circuit Voltage Waveform |
250V – 4,100V, Front Time1.2us ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
125A- 2050A, 8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
250V–4100V ±10% |
Peak Short Circuit Current |
125A–2050A ±10%@2Ω, 20.8-500A ±10%@12Ω |
Pulse Repetition Rate |
MAX. 1Hz (1s – 999s) |
Peak Voltage and Current Monitoring |
5,000V, 2,500A in the LCD Display |
Monitoring of EUT voltage and current |
Built-in 100:1 voltage measurement 10mV/A, max. 1,000A |
Dips and Interrupts: |
|
Standards |
EN IEC 61000-4-11 EN 61000-6-1, -6-2, CEMark |
Nominal current |
6 Amps Max. |
Interruption Time |
50µs up to 30s |
Phase angle interruption |
0 to 360 degrees |
Rise/ Fall Time |
1 to 5µs |
All Accessories
Item | Capabilities |
CDN2000-06-32 for Three Phase Coupling | Add three phase capability with automatic or manual three phase coupling networks. The CDN2000A-06-32 and CDN2000-06-32, can be used for EFT, CWG surge and ring wave. Coupling path selection is either automatic under software control, or manual on the CDN front panel. All coupling networks fulfill the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards. |
CDN2000A-06-63 for Three Phase Coupling |
Add higher current three phase capability with automatic coupling network CDN2000A06-63. This can be used for EFT, CWG surge and ring wave. Coupling path selection is automatic under software control. This coupling network fulfills the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards. |
CDN-A-3P100-480 F / F-S for 100A three Phase Coupling |
Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000. |
CDN-A-3P100-690 F / F-S for 100A three Phase Coupling | Three phase CDN with line voltages L to N/PE=398V and L to L=690V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx. |
CDN2000-06-25 Three Phase Coupling |
CDN2000-06-25 can be used for Combination wave, Ring wave and EFT testing. With an EMC PARTNER oscillatory wave tester, power and up to four data lines using the 100kHz and 1MHz oscillatory waves can be tested according to IEC61000-4-18. |
CN16-450C |
Single phase CDN for superimposing surge and EFT into power lines. EUT power supply up to 16A at 115V 400Hz. For use ONLY with TRA2004 or TRA2006 |
CN2000TT MC |
Test pistol for direct current injection of surge and 10/700µs according to IEC 61000-4-5. Cable length 1.5m with MC plugs. The test pistols can be used together with MIG system equipped with MC plug outputs on front panel or networks (NW). |
TEST SETUP |
Test package for EFT testing. This includes 1m cable with 2 x 470kOhm resistors and mechanical connections to the EFT reference plane. |
VERI50EFT |
50ohm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2 |
VERI1KEFT |
1kOhm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2. |
CN-EFT1000 |
Capacitive coupling clamp 100ohm according to IEC 61000-4-4 including 1m coax cable with BNC connectors. |
CN-BALUN |
Balanced/unbalanced transmission line transformer for EFT and 1MHz damped sine according to ANSI/IEEE C.37.90. Including coaxial cable with HV-BNC plugs (3x 0.5m), test tip + HV-BNC adapter (1 red, 1 black) and HV-BNC connector (2x). |
ESD2000 |
Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
EXT-TRA3000E |
ESD discharge module to fulfill IEC 61000-4-2 requirements. Self contained unit with high voltage generation. For full details, please refer to brochure “ESD Testers”. For use ONLY with TRA3000. |
ADAPTER EFT-CDN |
Adapter cable which enables EFT impulses to be measured at the output of either a single or three phase CDN as required by IEC 61000-4-4 Ed.2. |
CDN-UTP |
The CDN-UTP is a sophisticated coupling and de-coupling network for superimposing surge impulses on balanced communication lines in accordance with IEC 61000-4-5 (Figure 12: unshielded symmetrical interconnection lines), ITU-K20, K21 and FCC part 68. It is designed for 1.2/50µs and 10/700µs pulses up to 6.6kV. CDN-UTP is also available with 4 pairs (8 lines) as the CDN-UTP8 version. |
Standards
Common Standards for IMU Conducted Immunity Platform
- IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test.
- IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test.
- IEC 61000-4-5: Testing and measurement techniques - Surge immunity test.
- IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test.
- IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test.
- IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests.
- IEC 61000-4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0Hz to 150kHz.
- IEC 61000-4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.
- IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase