Data SheetUser ManualAs a leader in immunity test equipment rentals, we offer rentals of a variety of transient test systems designed for testing up to 15kV and CDNs up to 125Amps. Our diverse inventory includes ISO 17025 calibrated equipment from Teseq, EM Test, Haefely, and EMC Partner.
Overview
The Haefely Axos8 conducted immunity test generator allow for 6kV surge/combination wave testing, 5kV EFT/Burst, and a 7kV Ringwave (optional Dips and Interrupts are availible) and a built-in single phase coupler. This test systems is the higher voltage version of the Axos 5, including a Ringwave Function.
This Immunity Test Generator expandable functionality allows for quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards. This test equipment is user friendly with manual and automated test mode and software assisted test preparation. It provides a touch screen for efficient and effective manipulation of testing criteria to meet or a diverse set of testing needs. Both Axos units have front panel monitoring ports with built in attenuation allowing for quick ability to verify waveform.
This pulse generator allows for testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12 and optional external box for testing per EN/IEC 61000-4-11 and EN IEC 61000-4-29. The Axos unit can either be operated via front panel by large colour graphic interface or remotely from the PC. This product has the ability to change testing parameters while conducting tests and is useful for monitoring and debugging function during design phase as well as compliance and pre-compliance testing.
Specifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12 (Optional: EN/IEC 61000-4-11 & EN IEC 61000-4-29) |
General Data |
|
Control Power |
85V – 264V, 50/60 Hz |
External Trigger Input |
5 VTTL |
Trigger Output |
5 VTTL |
Sync Input |
BNC 10 V – 264 V AC |
Dimensions |
45 x 18 x 49cm, 17.11 x 7.02 x 19.29 inches |
Weight |
25kg, 55 lbs |
IEC/EN 61000-4-4 Burst/EFT |
|
Output Voltage |
0.2 – 5.0 kV ±10% |
Output Impedance |
50 Ohms |
Rise Time |
5 ns ± 30% |
Impluse Duration |
50 ns ±30% at 50 ohms, 50 ns – 15 + 100 ns at 1,000 Ohm |
Spike Frequency |
1 Hz – 1 MHz |
Burst Duration |
10 µs – 1 s |
Burst Period |
1 ms – 10 s |
Test Time |
1 s – 1,000 minutes |
Integrated single phase coupling/decoupling network |
264 V AC/16 A 220 V DC/10 A |
IEC/EN 61000-4-5 Surge Waveform |
|
Max Voltage |
0.2 – 7.0 kV ± 10% |
Voltage Rise Time |
1.2 µs ± 30% |
Voltage Duration |
50 µs ± 20% |
Output Impedance |
2 Ohms |
Phase Sync |
0 - 359°with 1° steps or asynchronous mode |
Output Current |
0.1 – 2.5 kA ±10% |
Current Rise Time |
8 µs ± 20% |
Current Duration |
20 µs ± 20% |
Integrated single phase CDN |
264 V AC/16 A, 220 V DC/10 A |
IEC/EN 61000-4-11 Dips & Interrupts |
Also IEC / EN 61000-4-29 |
Max Voltage |
264V AC/DC |
Max Current |
16 A AC/DC continuous, 40 A for 3 seconds |
Interupt Dip Level |
0%, 0% - 99% with external voltage source |
Interrupt Time |
.5 period – 800 periods, 100 µs – 1000 minutes |
Interval Time |
1 period – 800 periods, 100 µs – 1000 minutes - asynch |
Test Time |
1 s – 1000 minutes |
Phase Sync |
0-359 degress 16/40/50/60 Hz |
RMS Voltage and Current Monitor |
BNC output 100:1V – 10A/V |
IEC/EN 61000-4-12 Ed. 2 Ring Wave |
|
Max Voltage |
0.2 – 7.0 kV ± 10% |
Frequency |
100 kHz |
Rise Time |
OC 5 µs; SC 1 µs |
Impedance |
12 Ohm, 30 Ohm |
Phase Sync Accuracy |
± 1 degree |
Repetition Rate |
Up to 30 pulses / min |
All Accessories
Item | Capabilities |
DIP 116 | Automatic Dips Transformer 16 A 40/70/80% |
FP-EFT 32M |
3-Phase CDN EFT/Burst 32 A / 690 V |
FP-EFT 100M2 |
3-Phase CDN EFT/Burst 100 A / 690 V |
IP4B | Capacitive Coupling Clamp for EFT/Burst |
FP-COMB 32 |
Automatic 3-Phase / 32A CDN Surge and EFT/Burst 2 |
FP-SURGE 100M2 |
3-Phase CDN Surge 100A / 690 V |
PCD 121 |
Symmetrical Data & Control Line Coupler |
PCD 126A |
Asymmetrical Data & Control Line Coupler |
DEC 5 |
Symmetrical Data & Control Line Decoupler |
DEC 6 |
Symmetrical Data & Control Line Decoupler |
DEC 7 |
Asymmetrical Data & Control Line Decoupler |
MSURGE-A |
Magnetic Field Test IEC / EN 61000-4-9 |
VTM 15000 |
Isolation Test 1.2/50 us up to 10 kV |
VTM 15000/05 |
Isolation Test 1.2/50 us up to 10 kV / 0.5J |
PDP 8000 |
HV Differential Probe 1000:1 for Surge |
CP 101 |
Current Probe Model for Surge |
ES |
External Emergency Stop Switch P12 |
WL |
External Warning Lamp P12 |
Standards
Axos 8 Testing Standards:
- IEC/EN 61000-4-4 EFT / Burst
- IEC/EN 61000-4-5 Surge Edition 2 & 3
- IEC/EN 61000-4-9 Imp Magnetic Field
- IEC/EN 61000-4-11 AC Dips and Interrupts
- IEC/EN 61000-4-29 DC Dips and Interrupts
- IEC/EN 61000-6-1 Generic Residential
- IEC/EN 61000-6-2 Generic Industrial
- IEC/EN 60335-1 Household
- IEC/EN 60601-1 Medical
- and many more
Video
Axos8 - Capabilities, Setup, & Software: Transient Specialists
Description: This video is an overview of the Axos8 multi function conducted immunity generator. It provides a basic overview, including capabilities, how to setup the equipment, and additional testing considerations. This video also includes changing testing parameters through the software providing insight into how testing is conducted with this Haefely conducted immunity generator.