Description
Overview
The UCS 500N5E by EM Test is an EMI test generator designed for EFT/Burst testing to 5.5kV with a built-in single phase coupler. A2LA accredited calibration is included in the EMC rental equipment price. This immunity test product can be operated manually from the front panel or by remote via the built-in USB or GPIB interface.This EM Test Immunity Test Generator can be operated via Front panel menu and function keys enable the user to program his test routines quickly and accurately.
Data Sheet User ManualSpecification
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, & CE Mark |
Integrated CDN: |
|
AC Voltage and Current |
300V/16A; 50/60Hz |
DC Voltage and Current |
300V/10A |
EFT Burst 5/50ns: |
|
Standards |
EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50µs pulse width -15ns/+100ns |
Voltage Amplitude |
200-5,500V ±10%, 100V-2,750V ±10% into 50Ω |
Burst Duration |
td = 0.10ms - 999ms |
Burst Period |
tr = 10ms - 9,999ms |
Frequency |
f = 0.1kHz - 1,000kHz |
All Accessories
Rent coupler decoupler networks (CDN)s & accessories from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
UCS 500N5 Full Accessory List
Item | Capabilities |
V4780 S2 |
EMTest automated external transformer for the UCS 500n7 and UCS 500n5 generators to perform the dips and interrupts test for EN IEC 61000-4-11. |
CNI 503 |
3PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE |
MV 2616 |
MOTORISED VARIAC FOR VOLTAGE VARIATION |
V 4780 | TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS |
V 4780S2 |
TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS |
CNV 504/508 |
SURGE COUPLING/DECOUPLING NETWORKS FOR SIGNAL/DATA LINES |
MS 100N |
MAGNETIC FIELD COIL FOR POWER-FREQUENCY AND PULSED MAGNETIC FIELDS |
HFK |
CAPACITIVE COUPLING CLAMP |
CA EFT KIT |
VERIFICATION KIT FOR EFT/BURST PULSES |
KW50 |
100:1 divider, 50 ohm |
KW1000 |
500:1 divider, 1,000 ohm |
CNV 504Nx |
Coupling network for 4 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
CNV 508Nx |
Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
CNI 508N2 Assembly |
Set of coupling/decoupling and protection networks for testing unshielded and shielded high-speed communication lines (Ethernet lines |
V 4780 |
Tapped autotransformer as per IEC 61000-4-11 Ed.2 |
V 4780 S2 |
Tapped autotransformer as per IEC 61000-4-11 Ed.2 with automatic change of tap |
Standards
Widely Used Standards
Below is a list of common standards for this conducted immunity generator. This is by no means the only standards that it can cover. Please confirm prior to renting as capabilities are often based upon accessories.
- ANSI/IEEE C62.41
- ECE-R10
- EN 61000-4-11
- EN 61000-4-12
- EN 61000-4-29
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-8
- EN 61000-4-9
- EN 61000-6-1
- EN 61000-6-2
- EN 61543
- IEC 60255-22-5
- IEC 61000-4-11
- IEC 61000-4-12
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- IEC 61008-1
- IEC 61009-1
- IEC 61326
- IEC 61850-3
- IEEE 1547
- ITU-T K.20
- ITU-T K.21
- ITU-T K.45
- UL 1741
- UL 244
- UL 943