Ask Us About: ANSI/IEEE C37.90 - Rent Relay & Systems EMI Test Equipment
Transient Specialists
Filters
Recent Views
ANSI/IEEE C37.90 - Rent Relay & Systems EMI Test Equipment
- 5kV Surge & 5.5kV EFT Transient Pulse System
- CDN 300v/16amp AC/DC (32Amp Units Available)
- External Power & Dataline CDN Rentals
- 5kV Surge & EFT/Burst Pulse Generator
- Built-in CDN 264V/16Amps AC & 220V/10Amps DC
- Easy to Use & 3-Phase CDN FP-COMB 32 Rentals
- Haefely 3-Phase Surge & EFT CDN 480v/32amps
- Used with Axos 5/8 Series of Pulse Generators
- Compliant to IEC 61000-4-5/4 Coupling Methods
- EFT & Surge Coupling Decoupling Network
- Maximum 480 Volts 32 Amps AC
- Used with EM Test NX5/NX7 Generators
- 3-Phase Surge & EFT CDN 480 Volts 32 Amps
- Used with Teseq NSG 3060/3040 Generator Series
- Compliant to IEC 61000-4-5/4 Coupling Methods
- EM Test Capacitive Coupling Clamp (CCl)
- EFT/Burst Testing on I/O & Data Lines
- Compliant to EN/IEC 61000-4-4
- 16kV Air & Contact Discharge Test Levels
- Mobile Easy to use IEC 61000-4-2 Solution
- Touch Screen, Simple, 100 Volt Steps
- Haefely Coupling Clamp Clamp (CCL)
- Designed as per IEC 61000-4-4 Edition 3
- EFT/Burst testing of signal and data lines
- Automatic 690V/125A 3-Phase Surge & EFT Coupler
- Compliant Current Ratings <32, 63, 125Amps
- Must be Used with 400Volt NX5/NX7 Models
- 80 MHz - 1 GHz 250 Watts Output (Psat)
- 200 Watts P1dB & Highly Efficient
- Class A RF Power Amplifier
- 5kV Surge & 5.5kV EFT Transient Pulse System
- CDN 400v/16amp AC/DC Model
- Ideal for higher voltage DC DUT
- 4 kHz - 400 MHz 100 Watts Output (Psat)
- 75 Watts P1dB & Highly Efficient
- Class A RF Power Amplifier
- 700 MHz - 6 GHz 60 Watts Output (Psat)
- 50 Watts P1dB & Front Panel Gain Control
- Class A Broadband Power Amplifier
- 4kV Surge & EFT Transient System
- Built-in 300v/16amps AC & DC CDN
- Software & ISO 17025 Calibration Included
- EMC Partner Capacitive Clamp
- Designed for EFT/Burst Testing I/O lines
- IEC 61000-4-4 & IEC 61000-4-18 DOW
- Automatic 690V/125A 3-Phase Surge & EFT Coupler
- Compliant Current Ratings <32, 63, 125Amps
- Must be Used with 400Volt NX5/NX7 Models
33 products
Overview
General Testing Information
ANSI/IEEE C37.90-2005 series of standards provides test levels and associated methods for relay and relay systems used in electrical equipment. This standard has several sections each relating to different EMI series of tests. The majority of these test are power on tests, excluding the insulation related testing involved in the surge withstand capabilities (SWC) tests. This standard covers several common causes interference including Electrostatic Discharge (ESD), radiated immunity, damped oscillatory pulses, electrical fast transients (EFT), and surge testing. Specific considerations needs to be given to DOW and Surge test given fairly unique requirements.
Common test sections:
ANSI/IEEE C37.90.1 - SWC DOW Pulses & EFT
ANSI/IEEE C37.90.2 - Radiated Immunity
ANSI/IEEE C37.90.3 - Electrostatic Discharge (ESD)
Test Equipment
C37.90 surge requirements include a .5 joules at each test level of the 1.2/50us waveform, often making additional test generators required. The EM Test VSS 500N6 offer a easy to use turnkey system for this and other .5 joule test requirement, often used with relay testing. This surge generator also meets the product based requirements of IEC 60255-27. The damped oscillatory waveform (DOW) test system designed by EMC Partner, the MIG-OS-OS1 offers a compliant solution to the corresponding section of C37.90. This solution offers 3-phase 480VAC/24amp equipment under test (EUT) and control via front panel.