Description
Overview
Coupling network for Common Mode testing .Coupling onto DC, AC single and three phase supplies. Used with TRA3000 C.
Data SheetUser ManualSpecifications
Common Standards |
|
AC Voltage and Current |
3 x 415V L-L, 240V L-N, Current limited by decoupler |
DC Voltage and Current |
300V, no current limit |
Generator impedance |
50 Ohm |
Coupler impedance | 50 Ohm |
Frequency range | DC to 60Hz for power test, Up to 2.5kHz for harmonics of power system, Up tp 150 kHz generated by switching in power electronics |
Sweep test | 15 Hz to 150 kHz 1-30V |
Power test on 1, 2, 4 lines | 16.67Hz, 50 Hz, 60Hz, 1V- 330V |
Packing List/Accessories
Included with Rental
Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping.
CN 16
- CN#
- MC Cords (3)
- U Shaped Jumpers (3)
- Printed Manual
- Calibration Documentation
- MC Connectors (3)
- Pelican Case