Description
Overview
This three-phase Coupling/Decoupling Network (CDN) for Surge Combination Wave, Ring Wave and EFT/Burst. It is fully compliant with the standard requirements of IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-12, ANSI C62.41 and others. It is automatic, changes phase angles and coupling method via selection from front panel of the Axos generator. This CDN must be used with the Axos series of immunity generators and cannot be used with other manufacturer's equipment.
Data Sheet User ManualSpecifications
Common Standards |
IEC/EN 61000-4-4, IEC/EN 61000-4-5 and IEC/EN 61000-4-12 |
CDN Inputs |
5 connectors - Banana socket front panel |
CDN Output |
5 connectors - Banana socket front panel |
Waveforms |
EFT/Burst Surge Combination Wave Ring Wave IEC/EN 61000-4-4 Ed. 3 IEC/EN 61000-4-5 Ed. 3 IEC/EN 61000-4-12 Ed. 2, C 62.41 |
Maximum EFT/Burst Input Voltage |
5kV |
Maximum Surge Combination Wave Input Voltage |
7kV |
Maximum Ring Wave Input Voltage | 7kV
|
Coupling Path Selection |
Automatic IEC + ANSI |
Synchronization |
10V to 480V input voltage 0° to 359°, step 1° Sync. on coupling path, output BNC rear panel |
Decoupling | |
Voltage AC |
Up to 480V AC 16.7Hz, 50Hz, 60Hz |
Voltage DC |
Up to 480V DC
|
Nominal Current |
32A |
EFT/Burst Input Voltage Range |
0.2kV - 5kV |
Surge Combination Wave Input Voltage Range & Ring Wave Input Voltage Range |
0.2kV - 7kV |
Synchronization |
10V to 480V input voltage 0° to 359°, step 1° |
All Accessories
Item | Capabilities |
DIP 116 | Automatic Dips Transformer 16 A 40/70/80% |
FP-EFT 32M |
3-Phase CDN EFT/Burst 32 A / 690 V |
FP-EFT 100M2 |
3-Phase CDN EFT/Burst 100 A / 690 V |
IP4B | Capacitive Coupling Clamp for EFT/Burst |
FP-COMB 32 |
Automatic 3-Phase / 32A CDN Surge and EFT/Burst 2 |
FP-SURGE 100M2 |
3-Phase CDN Surge 100A / 690 V |
PCD 121 |
Symmetrical Data & Control Line Coupler |
PCD 126A |
Asymmetrical Data & Control Line Coupler |
DEC 5 |
Symmetrical Data & Control Line Decoupler |
DEC 6 |
Symmetrical Data & Control Line Decoupler |
DEC 7 |
Asymmetrical Data & Control Line Decoupler |
MSURGE-A |
Magnetic Field Test IEC / EN 61000-4-9 |
VTM 15000 |
Isolation Test 1.2/50 us up to 10 kV |
VTM 15000/05 |
Isolation Test 1.2/50 us up to 10 kV / 0.5J |
PDP 8000 |
HV Differential Probe 1000:1 for Surge |
CP 101 |
Current Probe Model for Surge |
ES |
External Emergency Stop Switch P12 |
WL |
External Warning Lamp P12 |
Video
Axos8 - Capabilities, Setup, & Software: Transient Specialists
Description: This video is an overview of the Axos8 multi function conducted immunity generator. It provides a basic overview, including capabilities, how to setup the equipment, and additional testing considerations. This video also includes changing testing parameters through the software providing insight into how testing is conducted with this Haefely conducted immunity generator.
Axos 8 - Overview: Haefely Hipotronics
Description: This video by Haefely Hipotronics is the manufacturers video on how to setup and use the Axos series of conducted immunity generators. This video provides information on connections and running tests through the touch screen front panel of the equipment. It also provides information on modifying testing parameters and is followed by a Recap.