EMC Partner Video & System Overview
EMC Partner TRA3000
This video by HVT shows how to setup the EMC Partner TRA3000 with communication via a control PC.
System Overview
Data SheetUser ManualDescription
The EMC Partner TRA3000 C provides frequency sweep, short, and long test according to IEC 61000-4-16 based on the TRA3000 transient generator. This system is a combination of the transient generator, EXT-IMU C-Short, PS3 supply, coupled with associated network. The test system includes a laptop with corresponding software to allowing for remote control and expedited testing procedures.
Specifications
Common Standards |
IEC 61000-4-16, IEC 61000-4-4, IEC 61000-4-5 |
Integrated CDN: |
|
AC Voltage and Current |
300V/16A; 50 to 400Hz |
DC Voltage and Current |
300V/16A |
Common Mode Test: |
|
Standards |
EN IEC 61000-4-16 Continuous and Short Duration Test |
Continuous Duration Test |
30Vrms |
Source Impedance |
50 ohms |
DC Switching Time |
1-5µs |
Power Frequency Tests |
DC, 16.7Hz, 50Hz, 60Hz |
Power Harmonics Tests |
15Hz up to 150kHz |
Sweep Time |
1 decade/minute |
Short Duration Test Level |
0 – 300Vrms |
EFT Burst 5/50 ns: |
|
Standards |
EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Amplitude |
250-4,400V ±10%, 125V-2,200V ±10% into 50Ω |
Burst Duration |
td = 0.10ms – 30ms |
Burst Period |
tr = 1ms – 1,000ms |
Frequency |
f = 0.1kHz - 1,000kHz |
Combination Wave Surge: |
|
Standards |
EN/IEC 61000-4-5 , EN 61000-6-1, -6-2, CEMark |
Open Circuit Voltage Waveform |
250V – 4,100V, Front Time1.2us ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
125A- 2050A, 8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
250V–4100V ±10% |
Peak Short Circuit Current |
125A–2050A ±10%@2Ω, 20.8-500A ±10%@12Ω |
Pulse Repetition Rate |
MAX. 1Hz (1s – 999s) |
Peak Voltage and Current Monitoring |
5,000V, 2,500A in the LCD Display |
Monitoring of EUT voltage and current |
Built-in 100:1 voltage measurement 10mV/A, max. 1,000A |
Dips and Interrupts: |
|
Standards |
EN IEC 61000-4-11 EN 61000-6-1, -6-2, CEMark |
Nominal current |
6 Amps Max. |
Interruption Time |
50µs up to 30s |
Phase angle interruption |
0 to 360 degrees |
Rise/ Fall Time |
1 to 5µs |
Weight |
25kg, 55 pounds |